Leave Your Message

PTFE Lined Four-Way Cross Fitting - Durable Solutions from China Suppliers and Factory for Corrosive Media

,

Brand: Ruitu Automation

,

Product Origin: China

,

Type: Cross fitting with flanged connections, featuring a durable internal lining of polytetrafluoroethylene (PTFE).

,

Application: Ideal for pipeline systems handling highly corrosive media, enabling multi-directional diversion, confluence, or directional change of fluids.

,

Advantages: Our PTFE lining ensures exceptional resistance to strong acids and alkalis, making it perfect for harsh corrosive environments. The flanged connections guarantee stable installation and excellent adaptability. Additionally, this cross fitting offers low flow resistance and minimizes conveying loss, optimizing fluid dynamics.

,

As a trusted supplier and factory based in China, Ruitu Automation is committed to providing high-quality products designed for durability and performance in demanding applications.

,

    Core Overview

    PTFE Lined Four-Way Fitting is a corrosion-resistant pipe fitting widely used in chemical, pharmaceutical, metallurgical, and environmental protection industries. It features a PTFE lining inside a carbon steel or stainless steel shell, combining the corrosion resistance of PTFE with the mechanical strength of metal, making it ideal for transporting corrosive media such as acids, alkalis, salts, and organic solvents.

    Basic Specifications

    Item Details
    Product Name PTFE Lined Four-Way
    Executive Standards HG/T 21562, ASME B16.5, GB/T 12224
    Nominal Diameter DN15 – DN300 (1/2" – 12")
    Pressure Rating PN10, PN16, PN25, PN40 / Class 150, Class 300
    Structure Type Equal Cross, Reducing Cross
    Shell Material Carbon Steel (Q235B, 20#), Stainless Steel (304, 316L)
    Lining Material Polytetrafluoroethylene (PTFE)
    Lining Thickness 2.0–6.0 mm (Standard: 3.0–4.0 mm)
    Connection Type Flanged Connection (RF Raised Face, FM Female Face)
    Operating Temperature -20℃ to +180℃
    Applicable Medium Strong acids, strong alkalis, oxidants, organic solvents and other highly corrosive media
    Factory Inspection Hydrostatic pressure test, Spark pinhole leakage test (5kV)
    Main Applications Chemical, petrochemical, pharmaceutical, metallurgy, environmental protection, fluorine chemical, sewage treatment industries

    Typical Dimensions Table

    Nominal Diameter DN Outer Diameter (mm) Center-to-End (mm) Flange Outer Diameter (mm) Bolt Circle Diameter (mm) Lining Thickness (mm)
    15 21.3 40 90 60 3.0
    20 26.9 50 100 70 3.0
    25 33.7 65 115 80 3.5
    32 42.4 80 140 100 3.5
    40 48.3 100 150 110 3.5
    50 60.3 125 165 125 4.0
    65 76.1 160 185 145 4.0
    80 88.9 190 200 160 4.0
    100 114.3 250 220 180 4.5
    125 139.7 310 250 210 4.5
    150 168.3 380 285 240 5.0
    200 219.1 500 340 295 5.5
    250 273.0 630 405 355 6.0
    300 323.9 750 460 410 6.0

    Core Advantages

    Advantage Category Specific Content
    Corrosion Resistance PTFE lining can resist corrosion from most acids, alkalis, and organic solvents, with a corrosion resistance coefficient of up to 0.99
    Low Friction The friction coefficient of PTFE is only 0.04, which reduces the resistance of fluid transportation and saves energy
    Temperature Resistance Can work stably in the temperature range of -200℃ to 260℃, suitable for high and low-temperature environments
    Non-Stick Property The surface of PTFE is non-stick, which prevents medium deposition and facilitates cleaning
    Long Service Life The service life is 3-5 times longer than that of ordinary pipe fittings, reducing maintenance costs

    Frequently Asked Questions (FAQ)

    Q1: What are the main materials used in PTFE Lined Four-Way fittings?
    A1: The outer shell is typically made of Carbon Steel (such as Q235B, 20#) or Stainless Steel (such as 304, 316L), while the inner lining is made of premium Polytetrafluoroethylene (PTFE) to ensure maximum corrosion resistance.
    Q2: What is the standard thickness of the PTFE lining?
    A2: The lining thickness generally ranges from 2.0 mm to 6.0 mm. For most standard applications, a thickness of 3.0 mm to 4.0 mm is used.
    Q3: What temperature range can these fittings handle?
    A3: The standard operating temperature for our PTFE lined four-way fittings ranges from -20℃ to +180℃, though the raw PTFE material itself can withstand temperatures from -200℃ to 260℃ depending on the pressure and shell configuration.
    Q4: What inspections are conducted before the fittings leave the factory?
    A4: Every fitting undergoes rigorous quality checks, including a hydrostatic pressure test to verify structural integrity and a 5kV spark pinhole leakage test to ensure the PTFE lining is completely seamless and defect-free.
    Q5: Which industries commonly use PTFE Lined Four-Way fittings?
    A5: They are widely applied in chemical, petrochemical, pharmaceutical, metallurgy, environmental protection, fluorine chemical, and sewage treatment industries where highly corrosive media are processed.

    Leave Your Message